Transformer sizes

2000 kVA Transformer Buyers in Texas

Want to sell a 2000 kVA transformer in Texas? Texas Transformer Buyers buys new surplus, used, retired and failed units. Send nameplate and overall photos, quantity, location and condition so we can assess your equipment and make an offer.

2000 kVA (2 MVA)

Rating
2000 kVA (2 MVA)
Forms
Padmount transformers, Unit substations, Cast coil transformers
FLA
2,406 A @ 480 V
Area
All of Texas
Row of green three-phase padmount transformers staged in a Texas yard with a crane ready for loading
OUR PHOTOThree-phase padmount transformers staged for pickup and crane loading.

Sell a 2000 kVA transformer in Texas

A 2000 kVA transformer has a 2 MVA rating: kilovolt-amperes and megavolt-amperes describe apparent power capacity, not the unit's physical size. At this rating, equipment commonly takes the form of a three-phase padmount, a unit substation or a cast-coil or medium-voltage dry-type transformer.

These units serve industrial plants, campus buildings and data centers where substantial loads need a dedicated electrical supply. In Texas, a seller might have one available after a plant shutdown, building redevelopment, capacity upgrade or canceled construction project.

If you need a 2000 kVA (2 MVA) transformer buyer, send the actual equipment details rather than just the rating. We buy single units or whole lots, any brand, working or failed, and coordinate pickup across Texas from our Houston yard and office at 6402 McGrew St, Houston, TX 77087.

2000 kVA (2 MVA) three-phase full-load amps by voltage (A = kVA × 1000 ÷ (1.732 × V))
VoltageFull-load ampsTypical role
208 V5,551 ALow-voltage secondary
240 V4,811 ALow-voltage secondary
480 V2,406 ALow-voltage secondary
600 V1,925 ALow-voltage secondary
12,470 V93 ADistribution primary / secondary
13,800 V84 ADistribution primary / secondary
24,940 V46 ADistribution primary / secondary
34,500 V33 ADistribution primary / secondary

Check any rating with the kVA to amps calculator.

Identify the construction and voltage combination

Three-phase padmount transformers typically have an enclosed tank and cable compartments mounted on a ground-level pad. Dead-front construction means energized connections are insulated and shielded; loop-feed arrangements provide connections that support an incoming and outgoing distribution circuit.

Unit substations combine a transformer with associated incoming and outgoing electrical equipment. Tell us whether the sale includes only the transformer or also switchgear, switches, bus connections and other sections. Cast-coil transformers use windings encapsulated in resin rather than an oil-filled tank; other medium-voltage dry-type designs are also worth submitting.

Common combinations include a 12,470 V or 13,800 V primary feeding a 480Y/277 V secondary. Other units may have 24,940 V or 34,500 V primaries, or secondaries such as 208Y/120 V or 600 V. Primary is the supply-side voltage; secondary is the output-side voltage. Confirm both from the nameplate, including winding connections and available taps.

Indoor unit substation with transformer section close-coupled to switchgear in an electrical room
A unit substation: primary switch, transformer and low-voltage switchgear in one lineup.

Full-load amps and why the rating matters

For a three-phase transformer, full-load current equals kVA × 1,000 ÷ (1.732 × line-to-line volts). At 2000 kVA, the approximate current is 5,551 A at 208 V, 2,406 A at 480 V and 1,925 A at 600 V. These figures describe rated current, not a measurement of the equipment's present load.

On the higher-voltage side, the same rating gives approximately 93 A at 12,470 V, 84 A at 13,800 V, 46 A at 24,940 V and 33 A at 34,500 V. Use the table below or the transformer kVA-to-amps calculator to check the voltage shown on your plate.

Buyers care because the voltage and current must fit the intended system, including cables, bus connections and switchgear. A 208 V secondary has much higher current than a 480 V secondary at the same kVA, so two 2 MVA units are not automatically interchangeable.

What affects value and demand at 2 MVA

Demand for this size comes from projects with substantial three-phase loads, but suitability depends on more than capacity. Voltage combination, construction, winding material, condition and available documentation all affect how a unit fits another installation. A standard voltage arrangement can suit a different project than a specialized industrial configuration.

A used 2000 kVA (2 MVA) transformer can be worth evaluating even when it has been removed from service. Explain why it was retired, whether it was operating beforehand and whether it has damage, leaks or missing components. For a failed unit, describe the known fault without guessing at an unconfirmed diagnosis.

Impedance, the transformer's opposition to current flow expressed as a percentage, affects fault-current calculations and compatibility. Cooling ratings also matter: ONAN/ONAF identifies oil-natural, air-natural cooling and an additional fan-assisted rating. Send all listed ratings so an offer reflects the equipment being sold, not an assumed configuration.

Nameplate details and photos to send

Clear photos are the easiest starting point for assessing 2000 kVA (2 MVA) transformer specs. Photograph the entire nameplate straight on, with enough detail to read smaller entries. Our guide to reading a transformer nameplate helps identify the information that distinguishes otherwise similar units.

  • Include manufacturer, serial number, manufacturing date, three-phase rating, frequency and every listed kVA or MVA cooling rating.
  • Show primary and secondary voltages, tap positions, winding connections, impedance, winding material if listed, and cooling designation.
  • Send overall views, cable compartments or terminal areas where safely accessible, accessories, visible damage and any included substation sections.
  • Provide quantity, location, working or failed condition, storage history and any available test or maintenance records. For liquid-filled equipment, include fluid identification and existing PCB documentation; PCB means polychlorinated biphenyls.

Weight, rigging and trailer planning

Moving a 2 MVA transformer requires planning around its actual configuration. The nameplate lists exact weights; photograph those entries and identify separate sections or accessories. Do not estimate transport requirements from kVA alone, because construction and attached equipment change the load.

Send information about crane or forklift access, loading surfaces, gates, overhead obstructions and the route out of the site. Trailer selection depends on documented weight, dimensions and loading arrangements. Overall photos help show whether the unit is indoors, on a pad or still connected to adjacent equipment.

Disconnection and de-energizing stay with the seller or the seller's qualified electrical contractor. We coordinate freight and load-out with the seller, and price, payment terms and pickup details are agreed in writing before anything is loaded.

Get an offer for your Texas transformer

To sell a 2000 kVA transformer, call or text (951) 403-5738, email Industrial832@gmail.com, or submit your transformer for an offer. Include the photos and equipment details above, plus any access restrictions that could affect removal.

Whether your 2000 kVA (2 MVA) transformer in Texas is new in its crate, operating, retired or failed, we assess the details and respond with an offer. If the sale includes equipment of other sizes, list each unit separately so the complete lot can be evaluated together.

Frequently asked questions

Is a 2000 kVA transformer the same as a 2 MVA transformer?

Yes. Both describe the same apparent-power rating. Check whether 2000 kVA is the base cooling rating or a higher fan-assisted rating, because the nameplate may show multiple capacities.

Can you buy a 2000 kVA transformer with a 208 V secondary?

Yes, send its details for an offer. At 208 V, a three-phase 2000 kVA unit has approximately 5,551 A of full-load current. Include terminal and connection photos along with the nameplate.

Should I include the switchgear with a 2 MVA unit substation?

Describe exactly what is available and photograph each section. Identify the transformer separately from incoming switches, outgoing switchgear and connecting bus so the sale scope and load-out can be agreed clearly.

Can I sell a failed 2000 kVA transformer?

Yes. We buy failed transformers as well as working units. Send the known failure history, visible damage and any available test results so we can assess its actual condition.

Do you need test records to assess my transformer?

Send any records you have, but start with photos and nameplate information. For an oil-filled unit, available DGA, or dissolved gas analysis, reports can help explain its operating history and condition.

Have a transformer to sell?

Send the nameplate photo, a few overall shots and the location. We buy single units and whole lots anywhere in Texas.